How To Fit / Remove a R4 Receptacle

FITTING: The Naked Brass conductor must be 13mm

        Insert universal receptacle (rear side leading) into the front opening of the mounting frame.

        Press receptacle into mounting frame until it snaps and securely locked-in with the mounting frame

        Snap on the face plate if applicable

               

 

 

        Insert the stripped wire into the wire insertion openings on the back of the universal receptacle

        The gauge of the wire must be 13 mm to ensure a secured clamping contact once inserted

         To remove the wire, press down the wire release button next to the insertion opening and remove

        To remove the receptacle, insert a screw driver into the notch between the mounting frame and the receptacle

        Turn the screw driver clockwise or counter-clockwise to push away the locking clamp on the mounting frame from the receptacle

        At the same time, use you thumb to slightly push the operation side of receptacle down to release it from the mounting frame

        Apply the same sequence on the other side to release the receptacle from the mounting frame

        Gentle push the receptacle from its back to detach it from the mounting frame


 